IES-1085 4 x 802.3af + 4 x 802.3at + 2 GE SFP Managed Switch -40 to 75C, DIN-rail User Manual v1.00 - 1206
User Manual Page 10 Product Overview Industrial Managed Ethernet Switch Front View Package Contents When you unpack the product package, you s
User Manual Page 100 4. Example: The following example shows setting storm-control level LEVEL (30) to the interface fe1 (port 1): switch_a(config
User Manual Page 101 Use no storm-control multicast command to disable multicast traffic. 3. Command Syntax: storm-control multicast enable no sto
User Manual Page 102 switch_a(config)# 2. Usage: Use this command to statically configure a bridge entry to forward matching frames. 3. Command
User Manual Page 103 Port Mirroring 1. Command Mode: Interface mode Logon to Configure Mode (Configure Terminal Mode). Then logon to Interface mod
User Manual Page 104 4. Example: The following example sets new power budget 246 Watts to Switch: switch_a(config)#poe system-power-budget 246 swit
User Manual Page 105 4. Example: The following example sets new fixed power limit 15 Watts to the interface fe1 (port 1): switch_a(config)#interfa
User Manual Page 106 (no) poe power-down-alarm enable 4. Example: The following example shows the use of poe power-down-alarm enable to the interf
User Manual Page 107 3. Command Syntax: poe schedule-time DAY HOUR DAY <0-6> specifies Sunday ~ Saturday to Switch. HOUR <0-23> specifi
User Manual Page 108 Trunking Port Trunking Port Trunking 1. Command Mode: Interface mode Logon to Configure Mode (Configure Terminal Mode). Then
User Manual Page 109 STP Global Configuration, RSTP Port Setting, MSTP Properties, MSTP Instance Setting, MSTP Port Setting, Ring Setting G
User Manual Page 11 Product Highlights Basic Features Meets NEMA TS1/TS2 Environmental requirements such as temperature, shock, and vibration for
User Manual Page 110 BRIDGE-FORWARD Puts all ports of the specified bridge into the forwarding state. 4. Example: The following example enables or
User Manual Page 111 BRIDGE-FORWARD Puts all ports of the specified bridge into the forwarding state. 4. Example: The following example enables or
User Manual Page 112 GROUP <1-1> The ID of the bridge group to which this hello time is assigned. HELLOTIME <1-9> The hello BPDU interva
User Manual Page 113 GROUP <1-1> The ID of the bridge group to which this delay time is assigned. FORWARD_DELAY <4-30> the forwarding ti
User Manual Page 114 2. Usage: Use this command to set the cost of a path associated with a bridge-group. Use the no parameter with this command t
User Manual Page 115 Autoedge: 1. Command Mode: Interface mode Logon to Configure Mode (Configure Terminal Mode). Then logon to Interface mode. f
User Manual Page 116 switch_a(config)#interface fe1 switch_a(config-if)#spanning-tree edgeport switch_a(config-if)# MSTP Properties Region Name:
User Manual Page 117 3. Command Syntax: bridge GROUP revision REVISION_NUM GROUP <1-1> Specify the bridge-group ID. REVISION_NUM <0-255&g
User Manual Page 118 switch_a(config)#spanning-tree mst configuration switch_a(config-mst)# 2. Usage: Use this command to simultaneously add multi
User Manual Page 119 (1): switch_a(config)#bridge 1 instance 3 priority 0 switch_a(config)# MSTP Port Setting Bridge-Group Instance: 1. Command
User Manual Page 12 TRUNKING Port Trunking PORT-SECURITY Per-port programmable MAC address locking Up to 24 Static Secure MAC addresses p
User Manual Page 120 for a particular instance on a LAN, or which port should be the root port for an instance. A lower value implies a better prior
User Manual Page 121 Ring Setting Ring state: 1. Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode). The switch_a(con
User Manual Page 122 VLAN VLAN Mode Setting, 802.1Q VLAN Setting, 802.1Q Port Setting, Port Based VLAN 802.1Q VLAN Setting VLAN Database: 1. Comma
User Manual Page 123 disable Sets VLAN into a disable state. 4. Example: The following example enables the vlan VLANID (2) and name VLAN_NAME (vla
User Manual Page 124 2. Usage: Use switchport mode hybrid command to set the switching characteristics of the Layer-2 interface as hybrid, and clas
User Manual Page 125 Switchport hybrid allowed vlan: 1. Command Mode: Interface mode Logon to Configure Mode (Configure Terminal Mode). Then logo
User Manual Page 126 The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)# 2. Usage: Use th
User Manual Page 127 2. Usage: Use this command to set or remove the default VLAN for the interface. 3. Command Syntax: switchport portbase add|
User Manual Page 128 QoS Global Configuration, 802.1p Priority, DSCP Global Configuration QoS: 1. Command Mode: Configure mode Logon to Configure
User Manual Page 129 Strict Priority: 1. Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode). The switch_a(config)# pr
User Manual Page 13 Front Panel Display POWER This LED comes on when the switch is properly connected to power and turned on. Port St
User Manual Page 130 Logon to Configure Mode (Configure Terminal Mode). The switch_a(config)# prompt will show on the screen. switch_a(config)# 2.
User Manual Page 131 SNMP SNMP General Setting, SNMP v1/v2c, SNMP v3 SNMP General Setting SNMP Status: 1. Command Mode: Configure mode Logon to
User Manual Page 132 Location: 1. Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode). The switch_a(config)# prompt wil
User Manual Page 133 Logon to Configure Mode (Configure Terminal Mode). The switch_a(config)# prompt will show on the screen. switch_a(config)# 2.
User Manual Page 134 The switch_a(config)# prompt will show on the screen. switch_a(config)# 2. Usage: Use snmp-server trap-type enable linkDown
User Manual Page 135 2. Usage: Use snmp-server community get command to specify and no snmp-server community get command to remove get community n
User Manual Page 136 Add a user using snmp v3 with read-only or read-write access mode and without authentication. Use the no form of t
User Manual Page 137 The switch_a(config)# prompt will show on the screen. switch_a(config)# 2. Usage: Add a user using snmp v3 with read-o
User Manual Page 138 802.1x Radius Configuration, Port Authentication Radius Configuration Radius Status: 1. Command Mode: Configure mode Logon to
User Manual Page 139 switch_a(config)# Secret Key: 1. Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode). The switch
User Manual Page 14 Physical Ports The Industrial Managed Ethernet Switch provides: Number of ports 10/100Base-TX (802.3at) 4 10/100Base-TX (802.3
User Manual Page 140 switch_a(config)# Retransmit: 1. Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode). The switch
User Manual Page 141 switch_a(config-if)# Port Control: 1. Command Mode: Interface mode Logon to Configure Mode (Configure Terminal Mode). Then
User Manual Page 142 3. Command Syntax: dot1x timeout re-authperiod SECS no dot1x timeout re-authperiod SECS <1-4294967295> Specify the
User Manual Page 143 Other Protocols GVRP, IGMP Snooping, NTP GVRP GVRP: 1. Command Mode: Configure mode Logon to Configure Mode (Configure Termin
User Manual Page 144 The following example enables dynamic VLAN creation for bridge GROUP (1): switch_a(config)#set gvrp dynamic-vlan-creation enabl
User Manual Page 145 The following example sets GVRP applicant state to active on the interface fe1 (port 1): switch_a(config)#set gvrp applicant st
User Manual Page 146 (VLAN) when no multicast routing protocol is configured in the subnet (VLAN). When enabled, the IGMP Snooping querier s
User Manual Page 147 Use ip igmp version command to set the current IGMP protocol version on an interface. To return to the default version, use the
User Manual Page 148 Then logon to Interface mode. vlan1.1 means vlan 1. The switch_a(config-if)# prompt will show on the screen. switch_a(config)#i
User Manual Page 149 4. Example: The following example configures a maximum response time of 8 seconds on vlan1.1: switch_a(config)#interface vlan
User Manual Page 15 Switch Management Web-based browser interface The switch also boasts a point-and-click browser-based interface that lets user ac
User Manual Page 150 2. Usage: Use ip igmp snooping report-suppression command to enable report suppression for IGMP versions 1 and 2. Use the n
User Manual Page 151 The switch_a(config)# prompt will show on the screen. switch_a(config)# 6. Usage: Use ntp enable command to enable NTP for th
User Manual Page 152 3. Command Syntax: ntp sync-time 4. Example: The following example synchronizes time with NTP server: switch_a(config)#ntp s
User Manual Page 153 Daylight Saving Mode: 1. Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode). The switch_a(confi
User Manual Page 154 Specifications Applicable Standards IEEE 802.3 10Base-T IEEE 802.3u 100Base-TX/FX IEEE 802.3ab 1000Base-T IEEE 802.3z 1000Base-
User Manual Page 155 Appendix A DB9 DCE pin assignment Pin no. Name RS232 Signal name 1 DCD Data Carrier detect 2 RxD Received data 3 TxD Transmit
User Manual Page 156 Appendix B Time Zone Country and City Lists Europe MEZ-1MESZ Europe/Vienna, Europe/Berlin, Europe/Zurich MET-1METDST Africa/Tun
User Manual Page 157 RFT-11RFTDST Asia/Sakhalin, Asia/Magadan RFT-12RFTDST Asia/Kamchatka, Asia/Anadyr North America PST8PDT America/Los_Angeles, US
User Manual Page 158 America/Bahia, America/Sao_Paulo, America/Cuiaba, America/Montevideo, America/Catamarca, America/Rosario, Brazil/East WBST4WBDT
User Manual Page 159 Etc/Zulu, Etc/Greenwich, Etc/GMT-0, Etc/GMT+0, Etc/GMT0, Africa/Timbuktu, GMT+0, GMT-0, GMT0, Greenwich, Iceland, UCT, UTC, Uni
User Manual Page 16 Installation This chapter gives step-by-step instructions about how to install the switch: Selecting a Site for the Switch As
User Manual Page 160 Asia/Qatar, Asia/Riyadh, Asia/Aden, Etc/GMT-3 UCT-4 Indian/Mauritius, Indian/Reunion, Indian/Mahe, Asia/Muscat, Etc/GMT-4 UCT-5
User Manual Page 161 UCT12 Etc/GMT+12 North America (Canada) PST8PDT_CA America/Vancouver, America/Dawson_Creek, America/Whitehorse, America/Dawson,
User Manual Page 162
User Manual Page 17 DIN Rail Mounting Fix the DIN rail attachment plate to the back panel of the Media Converter. Installation: Place the Media Con
User Manual Page 18 Step 2: Disconnect the power cord if you want to shut down the switch. Back View Alarms for Power Failure Step 1: There a
User Manual Page 19 Connecting to Your Network Cable Type & Length It is necessary to follow the cable specifications below when connecting the
User Manual Page 2 Preface This manual describes how to install and use the Industrial Managed PoE (Power over Ethernet) Ethernet Switch. This switch
User Manual Page 20 Switch Management This chapter explains the methods that you can use to configure management access to the switch. It describes
User Manual Page 21 Administration Console (CLI) The administration console is an internal, character-oriented, Command Line Interface (CLI) for per
User Manual Page 22 Web Management The switch provides a browser interface that lets you configure and manage the switch remotely. applications d
User Manual Page 23 Management Architecture All of the management application modules use the same Messaging Application Programming Interface (MAPI
User Manual Page 24 SNMP & RMON Management Remote Monitoring (RMON) capabilities. Overview RMON is an abbreviation for the Remote Monitoring M
User Manual Page 25 WARM START COLD START LINK UP LINK DOWN AUTHENTICATION FAILURE RISING ALARM FALLING ALARM TOPOLOGY ALARM MIB-II defines a set o
Bridge Groups Supported The switch supports the following four groups of Bridge MIB (RFC 1493): - The dot1dBase Group a mandatory group that
User Manual Page 27 Web-Based Browser Management The switch provides a web-based browser interface for configuring and managing the switch. This int
User Manual Page 28 Understanding the Browser Interface The web browser interface provides groups of point-and-click buttons at the left field of th
User Manual Page 29 QOS Global Configuration, 802.1p Priority, DSCP SNMP SNMP General Setting, SNMP v1/v2c, SNMP v3 802.1X Radius Configuration,
User Manual Page 3 Table of Contents PREFACE ...
User Manual Page 30 System System Information The System name, Firmware version, System time, MAC address, Default gateway, DNS Server, VLAN ID, I
User Manual Page 31 System Name/Password 1. System Name: System Name . Type a system name if it is blank, or replace the current system name wit
User Manual Page 32 IP Address 1. IP Address: C IP Address text box and type a new address to change the IP Address. 2. IP Subnet Mask: C IP Su
User Manual Page 33 ARP Table Click ARP Table to view ARP Table. Route Table Click Route Table to view Route Table.
User Manual Page 34 Save Configuration 1. Load config from TFTP server: C TFTP Server text box and type the TFTP server IP address from where t
User Manual Page 35 Firmware Upgrade 1. Filename: C Filename text box and type the name of the file that you intend to upgrade it to the switch.
User Manual Page 36 Please follow the message on the screen during the firmware upgrade process. Do not turn off the power or perform other functi
User Manual Page 37 Firmware has been upgraded successfully to the switch. Reboot the switch after completing the upgrade process.
User Manual Page 38 Alarm Setting 1. Name: C Name drop-down menu to choose fe1~fe10 , ge1~ge2 , or Power1~Power3 Name drop-down list. 2
User Manual Page 39 Reboot Reboot: Reboot button to restart the switch. Logout Logout: Logout button to logout of the switch.
User Manual Page 4 ADMINISTRATION CONSOLE ...
User Manual Page 40 Port Configuration 1. Admin Setting: C Admin Setting drop-down menu to choose Link down or Link up Admin Setting drop-do
User Manual Page 41 Port Status View the Link Status, Speed, Duplex, and Flow control status for all ports. SFP Port: 1. View the Detected, Conn
User Manual Page 42 Rate Control 1. Ingress: C Ingress text box and type a new Rate to change the Ingress Rate Control for the port. Rate Values
User Manual Page 43 RMON Statistics Click Port 1 ~ Port 12 to view corresponding RMON Statistics. Per Port Vlan Activities Click Port 1 ~ Port
User Manual Page 44 Switching Bridging 1. Aging Time (seconds): Click the text box and type a decimal number as Bridging Aging Time in seconds. 2
User Manual Page 45 Static MAC Entry Static-MAC-Entry Forward: 1. Add MAC address: Add MAC address locked forwarding MAC address for the port. 2
User Manual Page 46 Port Mirroring 1. Mirror From: Choose Mirror From port from Port 1 ~ Port 12. 2. Mirror To: C Mirror To drop-down menu to C
User Manual Page 47 1. System Power Budget: System Power Budget new system power budget for Switch. 2. Submit: C Submit button when you finished
User Manual Page 48 Trunking Port Trunking Static Channel Group: 1. Trunk 1: Click Port 1 ~ Port 10 to assign ports to Trunk 1. (Maximum 4 ports
User Manual Page 49 STP / Ring Global Configuration 1. Spanning Tree Protocol: C Spanning Tree Protocol drop-down menu to Choose Enable or Dis
User Manual Page 5 Quick Start Guide This quick start guide describes how to install and use the Industrial Managed PoE (Power over Ethernet) Etherne
User Manual Page 50 RSTP Port Setting 1. STP Version: C STP Version drop-down menu to choose RSTP from STP Version drop-down list. 2. Port:
User Manual Page 51 MSTP Properties 1. STP Version: C STP Version drop-down menu to choose MSTP from STP Version drop-down list. 2. Regio
User Manual Page 52 max hops for a BPDU prevents the messages from looping indefinitely in the network. When a bridge receives a MST BPDU tha
User Manual Page 53 Configuration. Included VLANs 1. Instance ID: C Instance ID drop-down menu to choose instance ID from Instance ID drop-down
User Manual Page 54 MSTP Port Setting Port Instance Configuration 1. Instance ID: C Instance ID drop-down menu to choose instance ID from Insta
User Manual Page 55 Ring Setting Ring state 1. C Ring state drop-down menu from Ring state drop-down list to choose Enable or Disable to e
User Manual Page 56 VLAN VLAN Mode Setting 1. VLAN Mode Setting: C VLAN Mode Setting drop-down menu to Choose Tag-based VLAN or Port-
User Manual Page 57 802.1Q VLAN Setting Add VLAN: 1. VLAN setting: Click VLAN setting . The VLAN Setting window appears. 2. Add VLAN: C Add V
User Manual Page 58 Delete VLAN: 1. VLAN setting: Click VLAN setting . The VLAN Setting window appears. 2. Delete VLAN: C Delete VLAN button
User Manual Page 59 Mode drop-down list for the port. The port will be Tag port if you choose Trunk Mode for the port. And the port will be Tag o
User Manual Page 6 Power Input Terminal Block PW1 + 47 57VDC Power Ground PW2 + 47 57VDC Power Ground Earth Ground Relay Output 1A @ 250VAC
User Manual Page 60 QoS Global Configuration 1. QoS: C QoS drop-down menu from QoS drop-down list to choose Enable or Disable to enable or
User Manual Page 61 802.1p Priority 1. Priority: C Priority drop-down menu from Priority drop-down list to choose 0 ~ 3 for VLAN Priority 0 ~
User Manual Page 62 SNMP SNMP General Setting 1. SNMP Status: C SNMP Status drop-down menu from SNMP Status drop-down list to choose Enable
User Manual Page 63 SNMP v1/v2c 1. Get Community Name: Get Community Name textbox and specify a get community name. 2. Set Community Name: Se
User Manual Page 64 SNMP v3 Add User: 1. Add User: C Add User button. The SNMP V3 Setting window appears. 2. SNMP Version: C SNMP Version dr
User Manual Page 65 Delete User: 1. Delete User: C Delete User button. The Select User Name window appears. 2. Select User Name: C Select Use
User Manual Page 66 802.1x Radius Configuration 1. Radius Status: C Radius Status drop-down menu from Radius Status drop-down list to choose
User Manual Page 67 This key must match the encryption used on the radius daemon. All leading spaces are ignored, but spaces within and at the end o
User Manual Page 68 Port Authentication 1. Interface: C Interface drop-down menu from Interface drop-down list to choose the port to be set po
User Manual Page 69 Other Protocols GVRP GVRP Global Setting: 1. GVRP: C GVRP drop-down menu from GVRP drop-down list to choose Enable or Di
User Manual Page 7 Functional Description Meets NEMA TS1/TS2 Environmental requirements such as temperature, shock, and vibration for traffic cont
User Manual Page 70 3. GVRP registration: C GVRP registration drop-down menu from GVRP registration drop-down list to choose Enable or Disabl
User Manual Page 71 an entry between 1 and 124 (seconds). Default = 10. IGMP passive snooping: 1. Report suppression: report suppression - repo
User Manual Page 72 Enable Disable to enable or disable NTP for the Switch. 2. NTP Server (IP Address or Domain name): NTP Server textbox and sp
User Manual Page 73 Command Line Console Management The switch provides a command line console interface for configuration purposes. The switch can
User Manual Page 74 At the switch_a login: (or View Mode). switch_a login: root Basic commands Exec Mode (or View Mode) is the base mode
User Manual Page 75 Login timed out The login session to Exec Mode (or View Mode) has timed out due to an extended period of inactivity (60 seco
User Manual Page 76 Exit from Exec Mode (View Mode) At the switch_a> View Mode). switch_a>exit Privileged Exec Mode (Enable Mode) Logon t
User Manual Page 77 Commands Privileged Exec Mode (or Enable Mode) allows users to run commands as following. At the switch_a# prompt just press &
User Manual Page 78 question to display the command keywords or parameters along with a short description. switch_a#show ? Login timed out Th
User Manual Page 79 Exit from Privileged Exec Mode (or Enable Mode) At the switch_a# Mode (or Enable Mode). switch_a#exit Configure Mode (Confi
User Manual Page 8 Console Configuration Connect to the switch console: Connect the DB9 straight cable to the RS-232 serial port of the device and
User Manual Page 80 Commands Configure Mode (or Configure Terminal Mode) serves as a gateway into the modes as following. At the switch_a(con
User Manual Page 81 At the switch_a(config)# prompt just type in the full or partial command string then to display the command keywords or pa
User Manual Page 82 System System Information, System Name/Password, IP Address, ARP Table, Route Table, Save Configuration, Firmware Upgrade, Ala
User Manual Page 83 switch_a(config)# 2. Usage: Use enable password command to modify or create a password to be used when entering t
User Manual Page 84 4. Example: The following example shows the Route Table of switch: switch_a#show route-table IP Address IP Address/IP Subnet
User Manual Page 85 3. Command Syntax: ip default-gateway IP-ADDRESS no ip default-gateway IP-ADDRESS A.B.C.D specifies the IP address of the defau
User Manual Page 86 WORD specifies the file name to be loaded to switch. 4. Example: The following example specifies upgrading firmware (file name
User Manual Page 87 switch_a# Restore Default: 1. Command Mode: Privileged Exec mode Logon to Privileged Exec Mode (Enable Mode). The switch_a#
User Manual Page 88 1. Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode). The switch_a(config)# prompt will show on th
User Manual Page 89 # eload reboot the switch after completing the upgrade process. Alarm Setting Alarm-trigger if: 1. Command Mode: Confi
User Manual Page 9 Web Configuration Login the switch: Specify the default IP address (192.168.1.10) of the switch in the web browser. A login win
User Manual Page 90 4. Example: The following example enables alarm trigger on interface fe1 to switch: switch_a(config)#alarm-trigger if fe1 swi
User Manual Page 91 Logout 1. Command Mode: Exec mode or Privileged Exec mode Logon to Exec Mode (View Mode) or Privileged Exec Mode (Enable Mode).
User Manual Page 92 Port Configuration, Port Status, Rate Control, RMON Statistics, Per Port Vlan Activities Configuration Admin Setting:
User Manual Page 93 MODE specifies the duplex mode: auto, full, half. 4. Example: The following example shows the use of duplex MODE (full) to t
User Manual Page 94 3. Command Syntax: show interface IFNAME IFNAME specifies the name of the interface for which status and configurati
User Manual Page 95 LEVEL Threshold value -128 ~ 128℃. 4. Example: The following example sets high temperature alarm threshold 100℃ for SFP trans
User Manual Page 96 LEVEL Threshold value 0 ~ 131 mA. 4. Example: The following example sets high transmitter laser bias alarm threshold 131 mA fo
User Manual Page 97 information is desired. LEVEL Threshold value -30 ~ 8.16 dbm. 4. Example: The following example sets high received optical pow
User Manual Page 98 switch_a# 2. Usage: Use the show interface statistics command to display RMON statistics of interface. 3. Command Syntax: s
User Manual Page 99 Switching Bridging, Static MAC Entry, Port Mirroring, PoE, PoE Scheduling Bridging Aging Time (seconds): 1. Command Mode: Conf